Intra Corporeal Pneumatic Lithotriptor




LITHO-MED Digital is the device for Fragmentation of intra corporeal stone by direct contact lithotripsy with direct vision through endoscope.

LITHO-MED Digital is quite trustworthy instrument for Fragmentation of stones in kidney, ureter and bladder. During whole process, the safer lithotripsy is carried out. Digitally controlled microprocessor in single pulse and continuous pulse mode is revealing very accurate pulse.

LITHO-MED Digital having control unit, probes, hand piece and foot switch. It is a microprocessor based device. It operates with dry and clean compressed air by compressor or oxygen cylinder. It is a direct contact lithotripsy as a probe tip is directly touched with the stones in the bladder, ureter and kidney. Immediately after energizing the control unit by foot switch, at a Frequency From 1 cycle to 12 cycles the compressed air enters the hand piece and give movement to the piston hitting base of the probe, there upon, the stone is Fragmented through ballistic energy which is transmitted by the probe.

Control unit


Features :

-> Well balanced control unit with ABS plastic body

-> The unit is not only light weight and compact but also mobile

-> It minimizes the bilateral movement and also prevents probe escrution

-> This system is providing very accurate pulses in both single pulse operating mode as well as continuous pulse      operating mode

->Twelve options are provided in multiple modes starting From one pulse per second to twelve pulses per second

->The vital aspect is that there is no revelation of any thermal injury as no heat is generated inside

->Pressure is generated From 0.8 kg./cm2 , a knob is provided for pressure setting and the pressure is revealed From    digital display

->It is the most safer and efficient device, highly appreciated by the uro-surgeons

Frequencies :

Two type of Frequencies are procured,

SINGLE PULSE : For quite controlled Fragmentation the control unit is energized for single pulse by pressing the foot switch, on tip of the probe.

MULTIPLE PULSE : It is energized From one to twelve impacts per second on the tip of the probe by pressing the footswitch. It is indispensable mode to Fragment hard and large calculi. For the speedy Fragmentation the Frequencies can be kept between 4 impacts per second to 7 impacts per second.

Pressure :

-> Uretric stone     : 0.8 kg/cm2 to 2.5 kg/cm2

-> Kidney stone     : 1 kg/cm2 to 4 kg/cm2

-> Bladder stone    : 1 kg/cm2 to 3 kg/cm2

The pressure is adjusted keeping into view size and hardness of the stone

Technical Specification

CONTROL UNIT

Supply Voltage Operating     : 210-240 V A. C., 50 Hz

Pressure Minimum                : 0.8 Kg/cm2

Dimension                           : 113 mm x 215 mm x 200 mm

Weight                               : 1.250 Kg.

Pressure                             : Digital Control

HAND PIECE

Dimension      : 190 mm x 22 mm

Air Inlet         : Straight

PROBES

U.R.S.                 : 0.8 mm, 1.0 mm and 1.2 mm /L 610 mm

Bladder Stone      : 1.5 mm /L 500 mm

P.C.N.L.              : 2.0 mm / L 450 mm

                         : 2.5 mm / L 450 mm


LITHO-MED Digital Accessories


Handpiece With Suction




This is the device easy to handle by the maintenance staff. Reasonably light weight and durable. Hand piece is sterilized in formalin chamber or Cidex

THE SUCTION UNIT :

This suction unit is used with LITHO-MED Digital , Intra Corporeal Pneumatic Lithotripter. The suction is done through hollow probes and hand switch for PCNL and URS.

DISTINCT FEATURES :

-> During the process of lithotripsy, Fragmentation is done by obtaining distinct endoscopic vision. Not only this, a safe stone location is revealed

-> The specialty is that the suction is provided for residual fragments as well as stone dust, during and post lithotripsy


GENERAL INSTRCTIONS :

-> It is very necessary, to sterile the hand piece and probe preferably by formalin or Cidex sterilization before use. It is to be ensured that sterilization cap should be placed on hand piece during sterilization

-> Prior to using the system the surgeon must ensure that the system is in proper working condition and the hand piece is duly assembled

Handpiece




Probes




Probes are compatible with any world class Ureteroscope and Nephroscope. Available in all sizes.

Probes are sterilized in formalin chamber or Cidex.

Long lasting and cost effective.

Selecting the probes provided as standard accessories.

-> Uretric probes Size     : 0.8mm, 1.0mm, 1.1mm, 1.2mm, 1.5mm


-> PCNL probes Size       : 1.9mm, 2.5mm


-> Bladder probes Size    : 1.5mm


Foot Switch





Oxygen Regulator







  Copyright 2010 © Ark Meditech Systems. All rights reserved.                                                                       Website Created and Maintened by : Pramukh Web Solution.